Automatic firing up pellets and wood

ECOLOGICAL Wood burning grills

Hybrid fireplaces pellets and wood

Jaroslaw Rebiewski Track cycling world cup winner

Flame of the year 2018 Company of the year

Automatic cleaning Open the fireplace door once a month

Silver innovation competition award Grenoble 2018

  • Eco
  • NEW
ALEX AIR 10kW Twin glass  Automatic cleaning
ALEX AIR 10kW Twin glass  Automatic cleaning 1
ALEX AIR 10kW Twin glass  Automatic cleaning 2
ALEX AIR 10kW Twin glass  Automatic cleaning 3
ALEX AIR 10kW Twin glass  Automatic cleaning 4
ALEX AIR 10kW Twin glass  Automatic cleaning 5
ALEX AIR 10kW Twin glass  Automatic cleaning 6
ALEX AIR 10kW Twin glass  Automatic cleaning 7

ALEX AIR 10kW Twin glass Automatic cleaning

AA02


Functions
  • TWIN FUEL SYSTEM
    TWIN FUEL SYSTEM
    TWIN FUEL SYSTEM

    Several fuels can be burned in the fireplace:

    - A1 pellets or sawdust pellets (PREMIUM quality)

    - Hardwood logs

    - Sawdust briquettes

  • AUTO WOOD IGNITION
    AUTO WOOD IGNITION
    AUTO WOOD IGNITION

    The automatic ignition of the fireplace spontaneously ignites the wood logs.

  • AUTO PELLET IGNITION
    AUTO PELLET IGNITION
    AUTO PELLET IGNITION

    The fireplace has the function of automatic ignition of PELLET

  • BURNER DOUBLE CLEANING SYSTEM
    BURNER DOUBLE CLEANING SYSTEM
    BURNER DOUBLE CLEANING SYSTEM

    The fireplace is equipped with a dual-function cleaning system that allows unattended operation for up to 1 month without removing the ash

    1. Mechanical cleaning at the start of the cycle before each ignition using a mobile grid

    2. Air blast cleaning

  • ACTIVE CLEAN GLASS SYSTEM
    ACTIVE CLEAN GLASS SYSTEM
    ACTIVE CLEAN GLASS SYSTEM

    The fireplace is equipped with an active window cleaning system.

    The active cleaning system for the interior windows of the door and the side windows (Louis Corner and Louis Grand models) implements via the waterproof flame arrester a unique hot air supply system creating an air curtain on the glazed surfaces in the closed combustion chamber.

  • AUTO FUEL CHANGE
    AUTO FUEL CHANGE
    AUTO FUEL CHANGE

    The fireplace is equipped with an automatic transition mode from logs to Wood pellets

    After burning the WOOD, the fireplace will automatically ignite on the PELLET and maintain the room temperature.

  • CLOSED COMBUSTION CHAMBER
    CLOSED COMBUSTION CHAMBER
    CLOSED COMBUSTION CHAMBER

    The fireplace has a closed combustion chamber and can be used in rooms equipped with hot air recovery.

    A closed combustion chamber means that the hearth is completely airtight and that the air necessary for combustion is supplied at the base of the hearth, by a plug which can be connected either to the air coming from outside. from the building to another room.

    Most of the fireplaces available on the market have an air inlet from the room and an unsealed window to keep it clean while taking in air from the room. These are chimneys with an open combustion chamber.

  • System CONNECT Wi-Fi
    System CONNECT Wi-Fi
    System CONNECT Wi-Fi

    CONNECT SYSTEM

    INTERNET MODULE Wi-Fi


    Description of the device:

    The Internet module is a device that allows you to remotely control the operation of the home on the Internet.

    The user has remote access to all the options available in the chimney controller, using any device equipped with a web browser (smartphone, tablet, laptop, PC).

    Using the Connect system - you can, for example, turn the fireplace on or off, adjust the temperature in the rooms or check the condition of the fireplace.

    In addition, the fireplace via the Connect system will send the user an e-mail with information on the alarms or the information that we wish to receive in a particular phase of the fireplace's operation.

    As standard, the module is equipped with Wi-Fi and Ethernet LAN connectivity, it is possible to extend it with an additional module which allows the module to access the Internet via a GSM card.

    The Connect system can be used with any IWONA PELLETS fireplace.

Standard equipment
  • cheminée hybride,
  • conteneur à granulés 30 kg,
  • plateau,
  • accélérateur d'air d'admission automatique,
  • nettoyage automatique du double brûleur permettant un fonctionnement sans enlever les cendres jusqu'à 1 mois
  • Contrôle du ventilateur de distribution d'air chaud,
  • ensemble de capteurs,
  • allumeur,
  • contrôleur,
  • thermostat d'ambiance
  • minuterie hebdomadaire

Verre double en standard

 

 
Dimensions minimales après fabrication du caisson de cheminée ALEX AIR:
Profondeur: 80 cm
Largeur avec conteneur 30 kg: 80 cm
Product description

Parameters

ALEX AIR 10 kW Twin Glass

Size

Unit

Measurement

Power range

kW

4-10

Average fuel consumption at maximum power

kg/h

2,5

Average fuel consumption at minimal power

kg/h

1

Thermal efficiency

%

>85

Maximal thermal power of the device

kW

10

Average temperature of the exhaust gas

C

185

CO content for O2 = 13% average

mg/nm3

<200