FELIX AQUA ECO 13 kW Twin Glass Automatic cleaning
FQ02
-
AUTO PELLET IGNITION
-
BURNER DOUBLE CLEANING SYSTEM
-
ACTIVE CLEAN GLASS SYSTEM
-
CLOSED COMBUSTION CHAMBER
-
System CONNECT Wi-Fi
- fireplace,
- pellet tank 30 kg,
- tray,
- automatic intake air throttle,
- automatic double burner cleaning allowing operation without removing ash for up to 1 month
- water jacket cooler,
- set of sensors,
- igniter,
- controller,
- room thermostat,
- weekly timer,
Twin Glass in standard
Depth: 70 cm
Width with container 30 kg: 75 cm
-
Example of layout of a supply network or transport of pellets (Pellets)
-
Pellets container 300kg
-
Pellets container 200kg
-
Pellets container 100kg
-
CONNECT Wi-Fi system - Internet module
-
Blenda / metal cover frame
-
Protective grill for FELIX fireplace glass
-
Domestic hot water temperature sensor
-
Additional room temperature sensor
PROMOTION: When you buy a fireplace you get a 30% discount on the IWONA GRILLS
Fireplace with a water jacket for PELLET
- AQUA - Central heating
- Automatic firing up system
- Automatic fuel dosing system
Two devices in one: PELLET STOVE + FIREPLACE. Heating a house with a fireplace is a pleasure, a friendly climate of fire and a significant reduction in costs and lost space for the boiler room.
Elements made of acid-resistant steel, all laser-fired
Recommended for homes with recuperation
Equipped with original German fireplace glass
Built-in cooling coil
ECODESIGN certified fireplace
Entitling you to obtain financing for the purchase
Designed in 3D CAD SolidWorks technology
A fireplace with a water jacket has the HEAT BUFFER control function as standard
TWIN GLASS system - double glazing
IWONA PELLETS and IWONA GRILLS products are patented
Benefits
- Closed burning chamber
- Automatic - double cleaning of the furnance allows you to work without removing ash for up to 1 month
- Automatic firing up of PELLET
- Automatic combustion air inlet throttle
- Automatic power modulation Fuzzy Logic of 3 generation
- Automatic damper for combustion air intake from outside the building
- Active clean glass system
- Room thermostat
- Weekly timer
- Pellet tank sufficient for 2 days - 30 kg 3 days - 45 kg
- Opening the door 1 time per month
- A small amount of ash
- Quiet operation
- Water jacket cooler
- “CLOSED FURNACE”
IWONA PELLETS fireplaces, as a few on the market, have a closed combustion chamber, and thus can be used in buildings, which have the installation of air recuperation. IWONA PELLETS fireplaces take 100% of air needed for combustion from the outside of the building.
Most fireplaces available on the market have the air intake outside the building, while they do not have the closed combustion chamber, in which case most combustion air is taken from the room anyway.
- “AUTOMATIC CLEANING OF THE FURNACE”
We were the first ones who used in the IWONA PELLETS fireplaces the mechanism cleaning the furnace patented by us allowing the limitation of the opening of the doors in the fireplace up to 1 time a month. The furnace is automatically cleaned at a specified time keeping the hearth clean.
- “AUTOMATIC FIRING AND EXTINCTION”
Tthe pellet in the fireplaces are fired automatically within 5 minutes.
The intelligent controller, after exceeding the room temperature, makes the fire extinguish, while when it is reduced, it will automatically fire it again.
- “AUTOMATIC COMBUSION AIR INTAKE THROTTLE”
No more manual control of the combustion process in your fireplace!
The fireplace as a standard is equipped with the automatic combustion air intake throttle allowing the automatic adjustment of the combustion process.
- “ACTIVE CLEAN GLASS SYSTEM”
In cooperation with the closed combustion chamber, the fireplace was equipped with special hot air ducts creating a unique air curtain by the glass protecting it from dirt. The glass in the IWONA PELLETS fireplace is clean for many weeks.
- “THE BUILT-IN ROOM THERMOSTAT”
The fireplace as a standard is equipped with a room temperature sensor and the whole operation of the fireplace is focused on maintaining the desired temperature in the room. The controller can be equipped with an additional temperature sensor, which can be placed anywhere.
- “WEEKLY TIMER”
The fireplace as a standard is equipped with a weekly timer, which is used to program any temperature for any hour of any day of the week.
- “FUNCTIONALITY”
We have designed them so that their work is quiet, maintenance-free, clean and reliable.
- “ECONOMY”
The biggest advantage of our fireplaces is the economy.
Pellet consumption is very small. The adjacent pellet tray, which houses 45kg of pellet, is sufficient for 3 days of work.
- "EASY TO USE"
The entire heating process of our house is controlled by an advanced and at the same time easy to use controller with a display controlled via a control panel or as an option via the Internet or telephone. All the elements used in our fireplaces make them fully automatic and their operation is limited to pouring pellets into the container and pressing the enable button. You can easily set the desired room temperature, and the controller will select the amount of pellets fed to keep the temperature precisely.
- "SECURITY"
There is a small amount of pellets in the furnace during combustion. During a power failure or when the off command is given - the flame will go out after about 1 minute. This is a particularly important advantage for fireplaces with a water jacket.
- "ANY DESIGN"
Our pellet fireplaces as few on the market have the possibility of individual building that meets the requirements of each client.
- "EASY INSTALLATION"
We have designed our devices so that they are easy to install and as little as possible from standard wood inserts.
FELIX AQUA 13 kW TWIN Glass
Size |
Unit |
Measurement |
Power range |
kW |
6-13,2 |
Average fuel consumption at maximum power |
kg/h |
3 |
Average fuel consumption at minimal power |
kg/h |
1 |
Maximal thermal power supplied with fuel |
kW |
13,9 |
Thermal efficiency |
% |
91,4-90,6 |
Maximal output power given by the water coat, C.O power |
kW |
10 |
Average temperature of the exhaust gas EN 14875:2009 |
C |
170 |
CO content for O2 = 13% average |
mg/m3 |
<300 |